modem manufacturer: SCADA applications for modem data communication  
Data-Linc modems, tech support, industry alliances, sales channels, trade shows, information Industries Home About us News Sales Channels Partnerships/alliances Technical Services Products
product indicator List of Antennas and Cables NET620Ñ Serial to Ethernet Bridge List of Wire modems List of Wireless modems
Industrial Wireless Serial FHSS 900 MHz radio modem Industrial Wireless Ethernet FHSS 900 MHz radio modem Industrial Wireless Ethernet chassis mount 900 MHz radio modem Industrial Wireless Ethernet High Speed Broadband 900 MHz radio modem 900 MHz Industrial Wireless Discrete/Analog Wireles Multiplexer and Signal Conditioners 900 MHz Industrial Wireless modem Industrial 900 MHz Wireless discrete/analog I/O extender Industrial Wireless Serial FHSS 2.4 GHz radio modem Industrial Wireless Ethernet FHSS 2.4 GHz radio modem Industrial Wireless Ethernet chassis mount 2.4 GHz radio modem 2.4 GHz Industrial Wireless Discrete/Analog Wireles Multiplexer and Signal Conditioners Industrial Wireless Ethernet FHSS 2.4 GHz ETSI CE Mark 802.11b WiFi Compliant 2.4 GHz DSSS Wireless Modem 802.11b WiFi Compliant 2.4 GHz DSSS Wireless PCMCIA Card Modem

news rollover
Contact us
Site Map
Material handlinghydro-electric powerOil rig drillinggas pipelineminingforestry logging


Wireless Modems

Ethernet Radio

902-928 MHz
PLC rack mount
Data sheet
SRM6200E-SLC

2.4-2.4835 GHz
PLC rack mount
Data sheet
SRM6300E-SLC

2.4-2.4835 GHz
for EU countries
Data sheet
SRM6310E-EU

2.4-2.4835 GHz
Modicon Quantum Form Factor chassis mount
Data sheet
SRM6310E-QTM


Smart Spectrum FAQ

See also

Tech Services: Installation:
Antenna


NET620— Serial to Ethernet Bridge


NET620, offers simple low cost bridging of serial and Ethernet devices.
  • Serial to Ethernet bridging
    • Allen Bradley EtherNet/IP to DF1
    • ModBus TCP/IP to ModBus RTU
    • TCP or UDP terminal server
  • Quick web browser or supplied Set-LincTM software setup
  • Easy configuration via serial or Ethernet port
  • No "special" PLC configuration for bridging
  • A compact design with versatile mounting options

Data-Linc Group's advanced NET620 allows the integration of serial connected devices into Ethernet networks without a complicated network interface. No special PLC or PC configuration needed to integrate DF1 or ModBus RTU devices into EtherNet/IP or ModBus TCP/IP networks. When using the NET620 to bridge DF1 or ModBus RTU, the application is configured as if the serial device was Ethernet. The NET620 does the rest. Additionally, when used as a terminal server, any serial port redirect software will work (including "Freeware" software)-no proprietary software required. Configuring the NET620 is nearly effortless using either the supplied Set-Linc utility software or a web browser. In most cases all that is needed is to set the IP address and the serial port speed.

Power is provided by a three position terminal block with a input range of 10 to 28 VDC. The NET620 enclosure has the same footprint as the SRM6x20 with universal mounting flanges or optional DIN rail clips for flexible installation

The NET620 allows serial and Ethernet devices to communicate seamlessly without expensive interfacing equipment. The NET620 benefits the "bottom line" by making network design easier, more efficient and more cost-effective- saving money, time and effort.

Download a printable pdf (761 KB) version of this NET620 data sheet.
To read pdf files you need to get Adobe Acrobat Reader and install it on your PC.

^ Top of Page ^

 

NET620 Specifications

Included
CD. Set-LincTM Configuration software and User Manual
Cable. Cat5 (7')
Power. Wall mount 115 VAC supply, 12 VDC output


Interface
Ethernet. One 10BaseT (UTP) - Straight and crossover
Serial port. RS232 and RS485


Configuration
Set-Linc software or Web browser

DC power requirement
10 to 28 VDC via screw terminal and via Ethernet using Data-Linc DC power injectors

Operating Environment
Temperature. -40° to 167° F (-40° to 75° C)
Humidity 0 to 95% non-condensing

Enclosure
Standard: NEMA 1, 18 gauge steel; 2.75 X 3.75 X 8.1 in. (7 X 9.5 X 20.6 cm) using mounting brackets
Optional: 2.38 X 4.25 X 6.38 in (6 X 10.8 X 16.2 cm) using DIN rail mounting

Weight
1.5 lb (0.68 kg)

Enclosed Dimensions Diagram

P/N 155-09964-004 rev 10/04
Specifications subject to change without notice.
Smart Spectrum is a trademark of Data-Linc Group.
All other trademarks are the property of their respective owners.

Top of Page ^

Products

Features & Benefits | Focus Item | Product Selection Guides | Catalog | PDF Library | Order Information | FAQ
Tech Resources

Engineering Specifications | Articles & Technical Papers | Installation Information
Partners

GE Fanuc | Omron | Rockwell Automation | Schneider Electric | Siemens | Technology Partners
Industries

Security | Traffic | and other industry application notes and diagrams
Sales Channels

Distributors | System Integrators | OEMs
News

Tradeshows and Events | Press Releases | Newsletters
About Us

Overview | Office Locations/Contact Information


spacer
Data-Linc Group representatives in Asia Pacific. Wired & Wireless Solutions International
Head Office Asia Pac : Level 7, of 6 Help St, Chatswood, Sydney, NSW, Australia, 2067
Tel +61 2 9412 2100 • Fax +61 2 9403 7900•

© 1996-2006 Data-Linc Group. All rights reserved.
050104