RS2-16M 2LH SC
Product description
Description Managed Industrial ETHERNET Rail Switch, store and forward switching mode, Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
Port type and quantity 14 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity, 2 x 100BASE-FX, SM-cables, 1550 nm, SC sockets
Type RS2-16M 2LH SC
Order No. 943 797-003
More Interfaces
Power supply/signaling contact 1 plug-in terminal block, 6-pin
V.24 interface 1 x RJ11 socket
Standby port HIPER-Ring (Ringstruktur), RSTP (Rapid Spanning Tree Protocol), redundante Netz-/Ringkopplung, (Mast
Network size - length of cable
Twisted pair (TP) 0 - 100 m
Single mode fiber (LH) 9/125 µm (long haul transceiver) 24 - 86.6 km, 7 - 29 dB link budget at 1550 nm, A = 0.3 dB/km, 3 dB reserve, D = 19 ps/(nm x km)
Network size - cascadibility
Line - / star topology any
Ring structure (HIPER-Ring) 50 (reconfiguration time < 0.5 sec.)
Power requirements
Operating voltage 24 V DC (-25% to +30%)
Current consumption at 24 V DC max. 600 mA
Service
Diagnostics LEDs (power, link status, data, standby, redundancy manager), signal contact / fault relais (24 V DC / 1 A), RMON (statistics, history, alarms, events), port mirroring.
Configuration terminal SW, BOOTP, DHCP, DHCP option 82, auto-configuration adapter (ACA 11)
Security port security (MAC based and IP based), SNMPv3
Other services prioritization (IEEE 802.1D/p), VLAN (802.1Q), multicast (IGMP snooping/querier, GMRP), broadcastlimiter, SNTP (simple network time protocol), PTP (precision time protocol, IEEE 1588), flow control IEEE 802.3x
Redundancy
Redundancy functions HIPER-Ring (ring structure), RSTP (rapid spanning tree protocol), redundant network/ ring coupling (master/receiver), dual homing (master/receiver), redundant 24 V power supply
Ambient conditions
Operating temperature 0 °C to +60 °C
Storage/transport temperature -25 °C to +70 °C
Relative humidity (non-condensing) 10% to 95%
MTBF 20.6 years; MIL-HDBK 217F: Gb 25 °C
Mechanical construction
Dimensions (W x H x D) 110 mm x 131 mm x 111 mm
Mounting DIN Rail 35 mm
Weight 650 g
Protection class IP 20
Mechanical stability
IEC 60068-2-27 shock 15 g, 11 ms duration, 18 shocks
IEC 60068-2-6 vibration 1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz)
EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line
EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line
EN 61000-4-6 conducted immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz)
EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A
EN 55022 EN 55022 Class A
Approvals
Safety of industrial control equipment cUL 508 (E175531)
Hazardous locations cUL 1604 Class 1 Div 2 (E203960)
Germanischer Lloyd Germanischer Lloyd (15 662 - 00 HH)
Scope of delivery and accessories
Scope of delivery device, terminal block, operating manual
Accessories to order separately rail power supply RPS 30, RPS 60 or RPS 120, terminal cable, HiVision network management, auto-configuration adapter (ACA 11), 19" installation frame
Frontend Module
Modulation serial interface, web interface SNMP v1/v2/v3, HiVision, autom. topoloy detection (IEEE 802.1ab)